STROSE
LIVE FIRE
EXTINGUISHER TRAINING MODULE
| Product Code: NATO Stock No: |
STR 0079-20 21FF-266-0000 |
Manufacturing Specification |
|
| Towing Size | Length 220cms Width 150cms Height 145cms |
| Ground Clearance: | 25cms |
| Operating Height: | 200cms |
| Chassis: Frame: | Carbon Steel Axle: Carbon Steel Finish: Galvanised to BS 729 |
| Suspension: | Rubber Indespension Units Wheels: 500 X 10 8 ply Tyres Telescopic Screw Type Front Jockey Wheel Quick Release Drop Down Corner Jacks |
| Brakes: | Not Required |
| Towing Hitch: | 50mm Lockable to BS114/ISO 38543 |
| Stowage Locker: | Depth 75cms Width 80cms Height 65cms |
| Security: | Aluminium Roller Shutter Lockable |
| Carrying Capacity: | 120 kg |
| Stowage: | 2 x Fire Extinguishers 2 kg CO2 2 x Fire Extinguishers 6 kg Dry Powder 2 x Fire Extinguishers 9 ltr Foam 2 x Fire Extinguishers 9 ltr Water 1 x Fire Blanket 1 x Propane Bottle 13 kgs |
| Weight Fully Laden: | 500 kilo |
Control System |
|
|
"FAIL SAFE" remote control ruggedised handset controls the Gas Ignition System and Gas Supply Valves. |
|
| Electrical Supply | Independent 24v DC ( 2 x 12v 18ah dry cell batteries) |
| Fire Fuel | Propane LPG Regulated to BS3016 |
| Flexible Pipe | Stainless Steel BS 3218 Test Pressure 20 bar |
| Fuel Status: | Contents Gauge |
| Battery Status: | Display Meter |
| Battery Recharge: | 240v AC Charger 12vDC from Towing Vehicle |
| Gas Ignition: | Electronic |
| Gas Valves: | 24v DC Fail Safe Approved to EN161:1991 |
| Gas Regulator: | Calor Type 1991P |
| Pyroflash: | Le Maitre Silver Star 6001012L Hazard Class 1.4S |
Operating Specification |
|
| Operating Temperature: | -20 to + 40 deg.C |
| Power Input: | 24v DC |
| Remote Operating Range: | 15 - 20 metres |
| Handset Power: | Alkaline Batteries 4xAA or equivalent |
| Humidity: | 10% to 95% non condensing |
| Radio Frequency: | 418 MHz band |
THE MODULE COMPLIES WITH ALL RELEVANT REGULATIONS APPLICABLE IN THE EUROPEAN COMMUNITY